Common Issues
- NOMAG Flag after connecting the AV-Mag to the AV-30
- No power is being sent by the AV-30
- Check for 7v from the AV-30 on pin 13
- If pin 13 was paralleled then the Aux power may have been damaged
- No power is being sent by the AV-30
- The connection is poor from the AV-30 to the AV-Mag
- Check continuity
- Give a tug on the wires
- RS-232 connection is poor
- Check continuity
- Give a tug on the wires
- MAGCAL Flag does not extinguish after calibration
- Check the orientation in the install menu
- The AI shows a different heading than the DG
- Check that the installation and orientation has been completed on both
- Make sure you are displaying DG HDG and not GPS TRK
- Heading jumps or heading at some headings is wrong
- Grounding
- Coiling
- Interference from a motor